EDITIONEN·FR·ქართ

Accréditation Sans Frontières

International Accreditation of Healthcare Facilities

Standards › Standard 31 › Standard operating procedures (SOPs)

Standard operating procedure (SOP) · DEN-SOP-007 · Version 1.0 · Approved by the ASF Expert Committee

Supports: 31.21

At a glance

  • Each laboratory order states the specification and the material (DEN-FRM-008).
  • Items are disinfected before fitting and the step is recorded.
  • Only approved laboratories are used, and their records are kept.
  • The clinic can trace each item to its laboratory and to the patient.
  • Stop and get help straight away if: an item is fitted without disinfection, or from a laboratory not on the approved list.

1. Purpose

To make sure laboratory work is correctly specified, disinfected and traceable to an approved laboratory (31.21).

2. Scope

Applies to Clinical and support staff in the hospital
Locations All wards, clinics and departments of the facility
When Whenever the activity described is carried out
Does not apply to Activities covered by another document listed in section 15

3. Definitions

Term Meaning
Clinical lead The doctor or nurse in charge of the area at the time

4. Background

Dental laboratories make crowns, dentures and other work that goes in the patient’s mouth. The clinic must specify the work on a written prescription, use a quality-assured lab, and disinfect the work on return.

5. Responsibilities

Role Responsibility Competence
Clinical director Approves the laboratories Medical director
Clinician Writes the order and checks the item before fitting Clinical director

6. Materials and equipment

Item Requirement Condition
Records and forms named in this document Current version Checked before use

7. Safety

8. Before you start

9. Procedure

Step 1. Order.

  • Write the specification and material on the order (DEN-FRM-008).

Key point: Ordered.

Step 2. Receive and disinfect.

  • Disinfect the item on receipt and before fitting, and record it.

Key point: Disinfected.

Step 3. Fit and trace.

  • Fit the item and keep the link to the laboratory and the patient.

Key point: Fitted.

10. Decision points

11. Special situations

Situation Action
Out of hours Follow the same steps. Use the on-call contact on the wall of the area.

12. Escalation

13. Monitoring

Measure Target Frequency Owner If not met
Items fitted with disinfection recorded 100% Quarterly Clinical director Escalate to the medical director

14. Records

Record Kept in Retention
Record named in this document Patient record or the area file the period set by the facility’s records policy years

15. Training

16. Related documents

ID Title Use
DEN-FRM-008 Laboratory work order Record

17. Evidence

Reference Note
E-009 Based on the CDC guidelines for infection control in dental health-care settings (Kohn et al., 2003), ISO 17665 for moist-heat sterilisation, the Minamata Convention on Mercury (2013), IAEA Specific Safety Guide SSG-46 (2018), Council Directive 2013/59/Euratom, and the ADA guidelines on sedation (2016).
E-006 ASF Policy Framework v1.2. Adapted.
E-009 ASF Expert Committee consensus.

18. Change history

Version Date What changed Approval
1.0 the date of approval First version set Expert Committee approval

E-learning for this document

References

Download this document as PDF