Standards › Standard 31 › Standard operating procedures (SOPs)

Standard operating procedure (SOP) · DEN-SOP-001 · Version 1.0 · Approved by the ASF Expert Committee

Supports: 31.1

At a glance

  • Only instruments processed in a validated cycle are used (DEN-REG-001).
  • Instruments are packed in sealed sterile-barrier packs and dated.
  • Every cycle is monitored with the indicators named in this procedure (DEN-REG-001).
  • A failed indicator quarantines the load and triggers action.
  • Stop and get help straight away if: a load is released for use with a failed indicator, or with no cycle record.

1. Purpose

To make sure every reusable instrument is sterile before it reaches a patient, and that each cycle can be proved (31.1, 31.2).

2. Scope

Applies to Clinical and support staff in the hospital
Locations All wards, clinics and departments of the facility
When Whenever the activity described is carried out
Does not apply to Activities covered by another document listed in section 15

3. Definitions

Term Meaning
Clinical lead The doctor or nurse in charge of the area at the time

4. Background

Dental instruments that are not properly sterilised carry blood and infection from one patient to the next. A validated process, applied to every instrument, is what makes them safe to reuse.

5. Responsibilities

Role Responsibility Competence
Infection prevention lead Owns the validated cycles and the monitoring schedule Clinician or manager
Decontamination operator Processes instruments and records each cycle Infection prevention lead

6. Materials and equipment

Item Requirement Condition
Records and forms named in this document Current version Checked before use

7. Safety

8. Before you start

9. Procedure

Step 1. Clean and dry.

  • Clean each instrument by the manufacturer’s method before packing.
  • Dry fully so the sterilising agent can reach all surfaces.

Key point: Clean and dry.

Step 2. Pack and load.

  • Pack instruments in sealed sterile-barrier packs with a date.
  • Load the chamber within the validated load pattern.

Key point: Packed and loaded.

Step 3. Run and monitor.

  • Run the validated cycle for the instrument type.
  • Record the chemical and biological indicator results (DEN-REG-001).

Key point: Cycle recorded.

10. Decision points

11. Special situations

Situation Action
Out of hours Follow the same steps. Use the on-call contact on the wall of the area.

12. Escalation

13. Monitoring

Measure Target Frequency Owner If not met
Cycles with complete indicator records 100% Weekly Infection prevention lead Quarantine the loads and escalate to the clinical director

14. Records

Record Kept in Retention
Record named in this document Patient record or the area file the period set by the facility’s records policy years

15. Training

16. Related documents

ID Title Use
DEN-REG-001 Sterilisation cycle and load register Register
DEN-SOP-002 Dental unit waterline management Procedure

17. Evidence

Reference Note
E-009 Based on the CDC guidelines for infection control in dental health-care settings (Kohn et al., 2003), ISO 17665 for moist-heat sterilisation, the Minamata Convention on Mercury (2013), IAEA Specific Safety Guide SSG-46 (2018), Council Directive 2013/59/Euratom, and the ADA guidelines on sedation (2016).
E-006 ASF Policy Framework v1.2. Adapted.
E-009 ASF Expert Committee consensus.

18. Change history

Version Date What changed Approval
1.0 the date of approval First version set Expert Committee approval

E-learning for this document

References

Download this document as PDF
© 2026 Accréditation Sans Frontières · PHIG · Sheni Network