Standards › Standard 35 › Standard operating procedures (SOPs)

Standard operating procedure (SOP) · CRT-SOP-001 · Version 1.0 · Approved by the ASF Expert Committee

Supports: 35.1

At a glance

  • Every critical care patient is monitored continuously at the level set for their condition (CRT-FRM-001).
  • Alarm limits are set for each patient and recorded.
  • Every alarm is responded to, and any alarm switched off is recorded with a reason.
  • Equipment is checked at the start of each shift.
  • Stop and get help straight away if: a critical care patient is left with alarms off or no monitoring record.

1. Purpose

To make sure each critical care patient’s physiology is watched continuously and that alarms reach a person who can act (35.1).

2. Scope

Applies to Clinical and support staff in the hospital
Locations All wards, clinics and departments of the facility
When Whenever the activity described is carried out
Does not apply to Activities covered by another document listed in section 15

3. Definitions

Term Meaning
Clinical lead The doctor or nurse in charge of the area at the time

4. Background

A critically ill patient can deteriorate in minutes. Continuous monitoring, with alarms set to the patient’s acuity, shows the change while there is still time to act.

5. Responsibilities

Role Responsibility Competence
Critical care lead nurse Owns the monitoring standard and the alarm settings Clinical director
Bedside nurse Sets alarm limits, responds to alarms and records them Critical care lead nurse

6. Materials and equipment

Item Requirement Condition
Records and forms named in this document Current version Checked before use

7. Safety

8. Before you start

9. Procedure

Step 1. Set.

  • Set the monitoring level and individual alarm limits for the patient’s condition.

Key point: Set.

Step 2. Monitor.

  • Monitor continuously and respond to every alarm (CRT-FRM-001).

Key point: Monitored.

Step 3. Check.

  • Check equipment and alarm settings at the start of each shift and record any alarm switched off with a reason.

Key point: Checked.

10. Decision points

11. Special situations

Situation Action
Out of hours Follow the same steps. Use the on-call contact on the wall of the area.

12. Escalation

13. Monitoring

Measure Target Frequency Owner If not met
Patients with continuous monitoring and recorded alarm limits 100% Weekly Critical care lead nurse Escalate to the clinical director

14. Records

Record Kept in Retention
Record named in this document Patient record or the area file the period set by the facility’s records policy years

15. Training

16. Related documents

ID Title Use
CRT-FRM-001 Monitoring and alarm record Record

17. Evidence

Reference Note
E-009 Based on the Surviving Sepsis and critical care monitoring guidance, the NEWS2 early warning score (Royal College of Physicians, 2017), the Lancet Commission on Palliative Care (2018), and the WHO Global Patient Safety Action Plan 2021–2030.
E-006 ASF Policy Framework v1.2. Adapted.
E-009 ASF Expert Committee consensus.

18. Change history

Version Date What changed Approval
1.0 the date of approval First version set Expert Committee approval

E-learning for this document

No e-learning course is linked to this document yet.

Planned course: No e-learning course is linked to this criterion yet. A course is planned to cover it.

References

Download this document as PDF
© 2026 Accréditation Sans Frontières · PHIG · Sheni Network