Standards › Standard 57 › Standard operating procedures (SOPs)

SOP · RTH-SOP-003 · Version 1.0 · Approved by the ASF Expert Committee

Supports: 57.3

At a glance

  • Each treatment machine is checked on the documented quality assurance schedule (RTH-REG-001).
  • Output and safety interlocks are checked against the tolerance.
  • A machine that fails a check is taken out of clinical use until it is repaired and re-tested.
  • Stop and get help straight away if: a treatment machine is used clinically after a failed check or after its scheduled check is overdue.

1. Purpose

To make sure treatment machines deliver the planned dose safely (57.3).

2. Scope

Applies to Clinical and support staff in the hospital
Locations All wards, clinics and departments of the facility
When Whenever the activity described is carried out
Does not apply to Activities covered by another document listed in section 15

3. Definitions

Term Meaning
Clinical lead The doctor or nurse in charge of the area at the time

4. Background

To make sure treatment machines deliver the planned dose safely (57.3).

5. Responsibilities

Role Responsibility Competence
Medical physicist Runs the quality assurance schedule and records the results Clinical lead
Radiation oncologist Decides on clinical use after a failed check Clinical lead

6. Materials and equipment

Item Requirement Condition
Records and forms named in this document Current version Checked before use

7. Safety

8. Before you start

9. Procedure

Step 1. Check.

  • Run the scheduled output and safety checks and record them (RTH-REG-001).

Key point: Checked.

Step 2. Decide.

  • Compare each result with the tolerance. Take any failed machine out of use.

Key point: Decided.

Step 3. Re-test.

  • Re-test the machine after repair before it returns to clinical use.

Key point: Re-tested.

10. Decision points

11. Special situations

Situation Action
Out of hours Follow the same steps. Use the on-call contact on the wall of the area.

12. Escalation

13. Monitoring

Measure Target Frequency Owner If not met
Scheduled machine checks completed on time 100% Monthly Clinical lead Escalate to the hospital director
Failed checks with the machine taken out of use 100% Monthly Clinical lead Stop clinical use at once

14. Records

Record Kept in Retention
Record named in this document Patient record or the area file the period set by the facility’s records policy years

15. Training

16. Related documents

ID Title Use
RTH-REG-001 Machine quality assurance register Register
IMG-SOP-001 Imaging equipment quality assurance and calibration (existing, reused) SOP

17. Evidence

Reference Note
E-006 ASF Policy Framework v1.2. Adapted.
E-009 ASF Expert Committee consensus.

18. Change history

Version Date What changed Approval
1.0 the date of approval First version set Expert Committee approval