Standards › ASF Health Standards v10 › Standard 4

Standard 4

Environment and Accessibility

Environment and accessibility: handrails, toilets, lighting, beds, mobility equipment and trip hazards.

8
criteria
7
documents
3
e-learning courses
2
references

Criteria on this page

4.14.24.34.44.54.64.74.8

4.1
Handrails Are Fitted Where Patients Walk

Sturdy, continuous handrails are fitted on both sides of corridors, stairs and ramps where patients walk, so that a patient can hold on for the whole route.

Humanitarian settings
Recommended
Transition
Recommended
Standard
Recommended

Why it matters. A patient who is unsteady and walks along a corridor can fall where there is nothing to hold. Continuous handrails on both sides let them hold on for the whole route.

How the surveyor verifies this criterion

Sample. Walk 3 patient routes (ward corridor, stair or ramp, and route to the toilet) with the survey form on the day of assessment.

1. Handrails are fitted continuously on both sides of each corridor, stair and ramp.

Method. Walk each route and check both sides.

Evidence to show. Environmental falls-risk survey (ACS-FRM-001).

Pass when. Every route has continuous handrails on both sides.

2. The handrails are fixed and sturdy.

Method. Pull each handrail at three points on the walk.

Evidence to show. Survey record.

Pass when. No handrail moves under load.

3. Each quarterly survey is recorded.

Method. Check the survey dates for the last 12 months.

Evidence to show. Survey records.

Pass when. All four quarters are recorded, with findings closed.

Immediate fail (any one means the criterion is not met)

  • A route used by patients has no handrail on one side, with no marking or action.

Documents

Standard operating procedures (SOPs)

ACS-SOP-001 · Environmental falls-risk survey and hazard control
Forms

ACS-FRM-001 · Environmental falls-risk survey record
Policies

ACS-POL-001 · Environment and accessibility for safe movement

E-learning

References

  1. World Health Organization (2007). WHO Global Report on Falls Prevention in Older Age. Geneva: WHO.
  2. Facility Guidelines Institute and American Society for Health Care Engineering (2022). Guidelines for Design and Construction of Hospitals, 2022 edition. Chicago: FGI.
4.2
Toilets and Washrooms Have Correct Grab Bars

Grab bars in toilets and washrooms are placed for toilet transfer, both horizontal and vertical where the design allows, and are fixed so that they do not turn in their fittings.

Humanitarian settings
Recommended
Transition
Recommended
Standard
Recommended

Why it matters. Toilet transfers are one of the most common moments of falls in care. Grab bars in the right place and fixed firmly give the patient something to hold.

How the surveyor verifies this criterion

Sample. Check 5 toilets and washrooms, including at least one accessible cubicle, on the day of assessment.

1. Grab bars are placed for toilet transfer.

Method. Check each toilet for horizontal and vertical bars.

Evidence to show. Toilet and washroom check (ACS-FRM-002).

Pass when. Every toilet checked has grab bars placed for transfer.

2. Grab bars are fixed and do not turn in their fittings.

Method. Apply force to each bar on the walk.

Evidence to show. Toilet and washroom check.

Pass when. No bar turns under load.

3. Defects are reported and fixed.

Method. Check the defect record for the last 12 months.

Evidence to show. Defect record.

Pass when. Every defect is fixed within the set time.

Immediate fail (any one means the criterion is not met)

  • A grab bar turns in its fitting and is still used by patients.

Documents

Forms

ACS-FRM-002 · Toilet and washroom accessibility check

E-learning

References

  1. Facility Guidelines Institute and American Society for Health Care Engineering (2022). Guidelines for Design and Construction of Hospitals, 2022 edition. Chicago: FGI.
4.3
An Accessible Toilet Is Available Where Patients Need One

At least one toilet in the facility is accessible to a patient who uses a wheelchair, with enough clear floor space for a transfer and bars placed for that transfer, to recognised international design guidance for health facilities.

Humanitarian settings
Recommended
Transition
Recommended
Standard
Recommended

Why it matters. A patient who uses a wheelchair cannot use a toilet that is too small to turn in or has no bars to transfer with. At least one accessible toilet is needed for those patients to use the facility at all.

How the surveyor verifies this criterion

Sample. Check 5 toilets and washrooms, including at least one accessible cubicle, on the day of assessment.

1. At least one toilet is accessible for a wheelchair user.

Method. Measure the floor space and check the transfer bars.

Evidence to show. Accessibility check (ENV-FRM-001 and ACS-FRM-002).

Pass when. At least one accessible toilet is present, with the space and bars the guidance sets.

2. The accessible toilet is signed and reachable.

Method. Walk from the main route to the toilet.

Evidence to show. Walk record.

Pass when. The route is clear and signed.

3. The design meets recognised guidance.

Method. Compare the measurements with the guidance.

Evidence to show. Design check record.

Pass when. Measurements meet the guidance used.

Immediate fail (any one means the criterion is not met)

  • No toilet in the facility can be used by a wheelchair user.

Documents

Forms

ACS-FRM-002 · Toilet and washroom accessibility check

E-learning

References

  1. United States Access Board (2010). ADA Standards for Accessible Design. Washington, DC: U.S. Department of Justice.
  2. Facility Guidelines Institute and American Society for Health Care Engineering (2022). Guidelines for Design and Construction of Hospitals, 2022 edition. Chicago: FGI.
4.4
Toilet and Washroom Doors Allow Rescue

Toilet and washroom doors open outward, or can be released from outside in an emergency, so that a patient who has fallen or is unable to open the door can be reached and removed promptly.

Humanitarian settings
Essential
Transition
Essential
Standard
Essential

Why it matters. A patient who falls behind a toilet door that opens inward may not be found in time. A door that opens outward, or that can be released from outside, lets staff reach the patient in an emergency.

How the surveyor verifies this criterion

Sample. Check 5 toilets and washrooms, including at least one accessible cubicle, on the day of assessment.

1. Toilet and washroom doors open outward, or release from outside.

Method. Open and release each door from outside on the walk.

Evidence to show. Toilet and washroom check (ACS-FRM-002).

Pass when. Every door opens outward or releases from outside.

2. The release works in an emergency.

Method. Test the release from outside with a staff member.

Evidence to show. Test record.

Pass when. Each release works when tested.

3. Staff know how to release a door.

Method. Ask 3 staff to show the release.

Evidence to show. Staff check record.

Pass when. At least 2 of 3 staff show it correctly.

Immediate fail (any one means the criterion is not met)

  • A patient who has fallen behind a toilet door cannot be reached from outside.

Documents

Forms

ACS-FRM-002 · Toilet and washroom accessibility check

E-learning

References

  1. Facility Guidelines Institute and American Society for Health Care Engineering (2022). Guidelines for Design and Construction of Hospitals, 2022 edition. Chicago: FGI.
4.5
Lighting Supports Safe Movement

Corridors, stairs, toilets, washrooms and patient rooms are lit at a level that allows safe movement at all hours, with night lighting or motion-activated lighting where patients walk at night.

Humanitarian settings
Recommended
Transition
Recommended
Standard
Recommended

Why it matters. Patients get up at night and move in poor light. A dark corridor or toilet is where a fall is most likely. Adequate light, and night lighting, make the route safe at all hours.

How the surveyor verifies this criterion

Sample. Walk 3 patient routes (ward corridor, stair or ramp, and route to the toilet) with the survey form on the day of assessment.

1. Corridors, stairs, toilets, washrooms and rooms are lit at a safe level.

Method. Measure the light level at each point on the walk.

Evidence to show. Lighting check on the survey.

Pass when. Every area on the route meets the set level.

2. Night lighting or motion lighting is on the routes patients walk at night.

Method. Check the night route after dark.

Evidence to show. Night check record.

Pass when. Night lighting is working on every night route.

3. Lights that fail are reported and fixed.

Method. Check the fault record.

Evidence to show. Fault record.

Pass when. Every fault is fixed within the set time.

Immediate fail (any one means the criterion is not met)

  • A patient route at night has no working light.

Documents

Standard operating procedures (SOPs)

ACS-SOP-001 · Environmental falls-risk survey and hazard control
Forms

ACS-FRM-001 · Environmental falls-risk survey record

E-learning

References

  1. Facility Guidelines Institute and American Society for Health Care Engineering (2022). Guidelines for Design and Construction of Hospitals, 2022 edition. Chicago: FGI.
4.6
Beds and Chairs Are Set to Reduce Fall Risk

Patient beds are set to a low height when the patient is in them, brakes are locked, and the call system and personal items are within reach, so that a patient can get in and out safely.

Humanitarian settings
Recommended
Transition
Recommended
Standard
Recommended

Why it matters. A high bed is a common cause of falls when a patient climbs out. A low bed, with brakes on and the call bell in reach, keeps the patient safer in bed and on the way out.

How the surveyor verifies this criterion

Sample. Check 10 beds across the wards on the day of assessment, with the bed check records for the last 30 days.

1. Beds are set low when occupied, with brakes locked.

Method. Check each bed on the walk.

Evidence to show. Bed check (ACS-FRM-003).

Pass when. At least 90% of occupied beds are low with brakes locked.

2. The call system and personal items are within reach.

Method. Test the call system and check the reach from the bed.

Evidence to show. Bed check.

Pass when. Every bed checked has the call system in reach.

3. Beds are checked each shift.

Method. Check the records for the last 30 days.

Evidence to show. Bed check records.

Pass when. At least 90% of shifts have a recorded check.

Immediate fail (any one means the criterion is not met)

  • A patient is in a high bed with the brakes off.

Documents

Standard operating procedures (SOPs)

ACS-SOP-002 · Beds and mobility equipment check
Forms

ACS-FRM-003 · Bed, mobility equipment and call system check

E-learning

References

  1. World Health Organization (2007). WHO Global Report on Falls Prevention in Older Age. Geneva: WHO.
4.7
Walking Aids and Mobility Equipment Are Available and Checked

Walking aids, wheelchairs and other mobility equipment are available in the sizes needed, are in working order, and are checked on a defined schedule, so that a patient’s own aid or a facility aid is safe to use.

Humanitarian settings
Recommended
Transition
Recommended
Standard
Recommended

Why it matters. A patient who needs a walking frame or a wheelchair but finds none, or finds one that is broken, is put at risk. Having the right aids, in the right sizes, and checking them on a schedule keeps them ready.

How the surveyor verifies this criterion

Sample. Check 10 walking aids and wheelchairs from the register, and the mobility equipment check records for the last 3 months.

1. Mobility equipment is available in the sizes needed.

Method. Compare the stock sizes with the needs of current patients.

Evidence to show. Mobility equipment register (ACS-REG-001).

Pass when. Every size needed is in stock.

2. Equipment is in working order.

Method. Check each item on the walk.

Evidence to show. Mobility equipment register.

Pass when. Every item in use works.

3. Equipment is checked on the defined schedule.

Method. Check the check dates against the schedule.

Evidence to show. Mobility equipment register.

Pass when. At least 90% of items are checked on time, and faulty items are out of use.

Immediate fail (any one means the criterion is not met)

  • A faulty walking aid or wheelchair is in use with a patient.

Documents

Standard operating procedures (SOPs)

ACS-SOP-002 · Beds and mobility equipment check
Forms

ACS-FRM-003 · Bed, mobility equipment and call system check
Registers and logs

ACS-REG-001 · Mobility equipment register

E-learning

References

  1. World Health Organization (2021). Global Patient Safety Action Plan 2021–2030: Towards Eliminating Avoidable Harm in Health Care. Geneva: WHO. https://www.who.int/publications-detail-redirect/9789240032705
4.8
Routes Are Clear of Clutter and Trip Hazards

Routes that patients walk are kept clear of equipment, cables, boxes, mats and other objects that could cause a trip, and any hazard that cannot be removed is marked and managed.

Humanitarian settings
Recommended
Transition
Recommended
Standard
Recommended

Why it matters. A cable, a box or a mat on the floor is among the commonest causes of falls in a ward. Clear routes, with any hazard that cannot be removed marked, keep patients moving safely.

How the surveyor verifies this criterion

Sample. Walk 3 patient routes (ward corridor, stair or ramp, and route to the toilet) with the survey form on the day of assessment.

1. Patient routes are kept clear of trip hazards.

Method. Walk each route and record any hazard.

Evidence to show. Environmental falls-risk survey (ACS-FRM-001).

Pass when. No hazard is found on a route, or every hazard is marked.

2. Each hazard that cannot be removed is marked and managed.

Method. Check each marked hazard for the mark and the plan.

Evidence to show. Hazard record.

Pass when. Every marked hazard has a plan and an owner.

3. Staff are trained in falls prevention.

Method. Check the training record for the ward staff.

Evidence to show. Falls prevention training record (WRK-REG-005).

Pass when. At least 90% of ward staff are trained in the last 12 months.

Immediate fail (any one means the criterion is not met)

  • A trip hazard is left on a patient route with no mark and no action.

Documents

Standard operating procedures (SOPs)

ACS-SOP-001 · Environmental falls-risk survey and hazard control
Forms

ACS-FRM-001 · Environmental falls-risk survey record
Policies

ACS-POL-001 · Environment and accessibility for safe movement

E-learning

References

  1. World Health Organization (2007). WHO Global Report on Falls Prevention in Older Age. Geneva: WHO.

Additional resources: guidelines in the GMJ library

These guidelines are held in the GMJ guideline library (news.gmj.ge). WHO and PAHO are the issuing bodies; MSF guidelines are marked MSF.

Back to ASF Health Standards v10 · Standards Map · E-learning by standard · References

© 2026 Accréditation Sans Frontières · PHIG · Sheni Network